3 3 joints connections between rolls or sections of roof safety mesh.
Roof safety mesh regulations.
All mesh crossings shall be secured to prevent enlargement of the mesh opening.
The safety monitor is always a competent person 29 cfr 1926 500 b.
A ring fastener or hog ring used for joining side laps of roof safety mesh.
All mesh is to be lapped minimum of 150mm one square for purlins 2200 or greater to be lapped.
3 2 fixing connections between the roof safety mesh and the roof member.
The warning line system shall consist of ropes wires or chains and supporting stanchions 29 cfr 1926 502 f 2.
The maximum size of each safety net mesh opening shall not exceed 36 square inches 230 cm nor be longer than 6 inches 15 cm on any side and the opening measured center to center of mesh ropes or webbing shall not be longer than 6 inches 15 cm.
9 installation requirements 9 1 general the installation of roof safety mesh shall comply with the requirements of clauses 9 2 and 9 3.
Or on roofs 50 feet 15 25 m or less in width the use of a safety monitoring system alone is permitted 29 cfr 1926 501 b 10.
3 4 lapping where the sides of roof safety mesh are overlayed to prevent a gap forming between the two.
Appropriate lifting technique for long roof conforms to as nzs 4389 2015 roof safety mesh is installed by a competent person in a safe manner and in accordance with the manufacturer s instructions has its integrity inspected by a competent person prior to roof maintenance or removal.
Safety mesh has been tested and designed to meet testing standards developed by a national testing authority.
Longitudinal wire must face down with the cross wires facing up all longitudinal wires need to be wrapped around or through drilled holes in the purlins and tied off with a minimum of.